SetVolteParameters

From Opale Wiki
Revision as of 10:09, 2 April 2025 by Administrator (talk | contribs) (added Category:VOLTE using HotCat)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

This command allows to set all VoLTE parameters for a dedicated port and restart the modem if it is mandatory.

For voice call, the modem can be configured to either (CSFB, VOLTE or AUTO) :

  • accept the fallback in circuit switch (2G/3G),
  • force in VoLTE
  • automatic mode.

IMS APN, UserName, Password, Authentication type and the PDP Type are optional parameters.

The Authentication type can be NONE, PAP, CHAP or PAP_CHAP and the PDP type can take the value IPV4 or IPV4V6.

The MBN profile (optional) can be set to AUTO or with the name of a MBN profile present in the module.

In this case, if the MBN profile is different than the current profile, the modem will be restarted.

COMMAND

Command Line Arguments Returns
SetVolteParameters PortIndex, VolteMode, [ APN, UserName, Password, AuthType, PDPType, MbnProfile ] Error Code in case of error.

OUTPUT

Command status

EXAMPLE

~ # SetVolteParameters 1 VOLTE "" "" "" NONE IPV4 AUTO
SUCCESS